<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
  <channel>
    <title>Lake Shore Blog</title>
    <link>https://2877331.hs-sites.com</link>
    <description />
    <language>en-us</language>
    <pubDate>Mon, 27 Jan 2025 16:36:49 GMT</pubDate>
    <dc:date>2025-01-27T16:36:49Z</dc:date>
    <dc:language>en-us</dc:language>
    <item>
      <title>Paper references use of our VSM for electromagnetic acoustic transducer study</title>
      <link>https://2877331.hs-sites.com/paper-references-use-of-our-vsm-for-electromagnetic-acoustic-transducer-study</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/paper-references-use-of-our-vsm-for-electromagnetic-acoustic-transducer-study" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/blog_images/LakeShore-8607-VSM.png" alt="Lake Shore Cryotronics Model 8407 VSM" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;Electromagnetic acoustic transducers (EMATs) are widely used in various industries and scientific research applications for non-destructive testing of materials, including those in which they need to operate at elevated temperatures. The magnets used in EMATs to produce a bias magnet field can be either permanent magnets or electromagnets, and these magnets work in conjunction with magnetic coils to generate an alternating magnet field to induce eddy currents in the material. These interactions, in turn, generate ultrasonic waves for testing and evaluating materials.&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/paper-references-use-of-our-vsm-for-electromagnetic-acoustic-transducer-study" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/blog_images/LakeShore-8607-VSM.png" alt="Lake Shore Cryotronics Model 8407 VSM" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;Electromagnetic acoustic transducers (EMATs) are widely used in various industries and scientific research applications for non-destructive testing of materials, including those in which they need to operate at elevated temperatures. The magnets used in EMATs to produce a bias magnet field can be either permanent magnets or electromagnets, and these magnets work in conjunction with magnetic coils to generate an alternating magnet field to induce eddy currents in the material. These interactions, in turn, generate ultrasonic waves for testing and evaluating materials.&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=2877331&amp;amp;k=14&amp;amp;r=https%3A%2F%2F2877331.hs-sites.com%2Fpaper-references-use-of-our-vsm-for-electromagnetic-acoustic-transducer-study&amp;amp;bu=https%253A%252F%252F2877331.hs-sites.com&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>vibrating sample magnetometer</category>
      <category>magnetic material characterization</category>
      <category>electromagnetic acoustic transducer (EMAT)</category>
      <pubDate>Mon, 27 Jan 2025 16:36:48 GMT</pubDate>
      <author>webmaster@lakeshore.com (Lake Shore Cryotronics)</author>
      <guid>https://2877331.hs-sites.com/paper-references-use-of-our-vsm-for-electromagnetic-acoustic-transducer-study</guid>
      <dc:date>2025-01-27T16:36:48Z</dc:date>
    </item>
    <item>
      <title>Article examines performance of M81-SSM’s hybrid lock-in amplifier technology</title>
      <link>https://2877331.hs-sites.com/article-examines-performance-of-m81-ssms-hybrid-lock-in-amplifier-technology</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/article-examines-performance-of-m81-ssms-hybrid-lock-in-amplifier-technology" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/Step%20Response%20filters%20-%203%20Jan%202025%20at%2015.59.20.464-01-1.png" alt="Step response of IIR, FIR and Hybrid Filter" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;We have &lt;a href="https://2877331.hs-sites.com/new-app-brief-fir-vs.-iir-filtering-for-faster-lock-in-measurements"&gt;blogged before&lt;/a&gt; about the advanced filtering technology of our &lt;a href="https://www.lakeshore.com/products/categories/overview/material-characterization-products/measureready-m81-synchronous-source-measure-system/measureready-m81-synchronous-source-measure-system"&gt;M81-SSM synchronous source measure system&lt;/a&gt;, showing in a related application brief how the filtering can result in faster lock-in measurements. In particular, while discussing how the M81-SSM’s finite impulse response (FIR) filtering compares to the infinite impulse response (IIR) filtering traditionally used on a lock-in’s output filter, we point out that for suitable rejection of higher-frequency components, IIR filters can require long wait times for settled values in the measurement. In contrast, using the M81-SSM FIR output filter feature often allows for faster measurement times. However, that said, FIR filters often fail to provide adequate noise reduction due to their non-monotonic frequency response.&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/article-examines-performance-of-m81-ssms-hybrid-lock-in-amplifier-technology" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/Step%20Response%20filters%20-%203%20Jan%202025%20at%2015.59.20.464-01-1.png" alt="Step response of IIR, FIR and Hybrid Filter" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;We have &lt;a href="https://2877331.hs-sites.com/new-app-brief-fir-vs.-iir-filtering-for-faster-lock-in-measurements"&gt;blogged before&lt;/a&gt; about the advanced filtering technology of our &lt;a href="https://www.lakeshore.com/products/categories/overview/material-characterization-products/measureready-m81-synchronous-source-measure-system/measureready-m81-synchronous-source-measure-system"&gt;M81-SSM synchronous source measure system&lt;/a&gt;, showing in a related application brief how the filtering can result in faster lock-in measurements. In particular, while discussing how the M81-SSM’s finite impulse response (FIR) filtering compares to the infinite impulse response (IIR) filtering traditionally used on a lock-in’s output filter, we point out that for suitable rejection of higher-frequency components, IIR filters can require long wait times for settled values in the measurement. In contrast, using the M81-SSM FIR output filter feature often allows for faster measurement times. However, that said, FIR filters often fail to provide adequate noise reduction due to their non-monotonic frequency response.&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=2877331&amp;amp;k=14&amp;amp;r=https%3A%2F%2F2877331.hs-sites.com%2Farticle-examines-performance-of-m81-ssms-hybrid-lock-in-amplifier-technology&amp;amp;bu=https%253A%252F%252F2877331.hs-sites.com&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>noise rejection</category>
      <category>lock-in amplifier</category>
      <category>M81 synchronous source measure system</category>
      <pubDate>Fri, 17 Jan 2025 18:17:07 GMT</pubDate>
      <author>webmaster@lakeshore.com (Lake Shore Cryotronics)</author>
      <guid>https://2877331.hs-sites.com/article-examines-performance-of-m81-ssms-hybrid-lock-in-amplifier-technology</guid>
      <dc:date>2025-01-17T18:17:07Z</dc:date>
    </item>
    <item>
      <title>Read our app brief on the M81-SSM’s seamless autoranging technique</title>
      <link>https://2877331.hs-sites.com/read-our-app-brief-on-the-m81-ssms-seamless-autoranging-technique</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/read-our-app-brief-on-the-m81-ssms-seamless-autoranging-technique" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/Social%20Media-Blog-post-featured.png" alt="Read our app brief on the M81-SSM’s seamless autoranging technique" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;Traditional autoranging techniques often suffer from time and gain correction discontinuities, discouraging users from utilizing autoranging techniques in favor of smooth yet noisier measurements.&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/read-our-app-brief-on-the-m81-ssms-seamless-autoranging-technique" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/Social%20Media-Blog-post-featured.png" alt="Read our app brief on the M81-SSM’s seamless autoranging technique" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;Traditional autoranging techniques often suffer from time and gain correction discontinuities, discouraging users from utilizing autoranging techniques in favor of smooth yet noisier measurements.&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=2877331&amp;amp;k=14&amp;amp;r=https%3A%2F%2F2877331.hs-sites.com%2Fread-our-app-brief-on-the-m81-ssms-seamless-autoranging-technique&amp;amp;bu=https%253A%252F%252F2877331.hs-sites.com&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>device characterization</category>
      <category>M81 synchronous source measure system</category>
      <category>applications brief</category>
      <pubDate>Thu, 10 Oct 2024 14:03:57 GMT</pubDate>
      <author>webmaster@lakeshore.com (Lake Shore Cryotronics)</author>
      <guid>https://2877331.hs-sites.com/read-our-app-brief-on-the-m81-ssms-seamless-autoranging-technique</guid>
      <dc:date>2024-10-10T14:03:57Z</dc:date>
    </item>
    <item>
      <title>How to better characterize 2D materials with large contact resistance</title>
      <link>https://2877331.hs-sites.com/how-to-better-characterize-2d-materials-with-large-contact-resistance</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/how-to-better-characterize-2d-materials-with-large-contact-resistance" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/Common-mode-artifacts-CTA.png" alt="Characterize 2D Materials with Large Contact Resistance" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;a href="https://www.lakeshorecryotronics.com/common-mode-artifacts"&gt;&lt;/a&gt; 
&lt;p&gt;When studying 2D materials, researchers typically fabricate them into Hall bar structures to characterize their electronic and magnetic properties. For such applications, a four-probe longitudinal resistance measurement is effective at removing resistive contributions from contact or lead resistance, which is particularly important for low‑resistance devices. But the situation changes when measuring 2D samples with &lt;em&gt;large&lt;/em&gt; contact resistance. Even with a four-probe resistance configuration, common-mode to differential-mode conversion can occur, and this spurious signal conversion can lead to measurement error when performing transport experiments on such materials.&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/how-to-better-characterize-2d-materials-with-large-contact-resistance" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/Common-mode-artifacts-CTA.png" alt="Characterize 2D Materials with Large Contact Resistance" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;a href="https://www.lakeshorecryotronics.com/common-mode-artifacts"&gt;&lt;/a&gt; 
&lt;p&gt;When studying 2D materials, researchers typically fabricate them into Hall bar structures to characterize their electronic and magnetic properties. For such applications, a four-probe longitudinal resistance measurement is effective at removing resistive contributions from contact or lead resistance, which is particularly important for low‑resistance devices. But the situation changes when measuring 2D samples with &lt;em&gt;large&lt;/em&gt; contact resistance. Even with a four-probe resistance configuration, common-mode to differential-mode conversion can occur, and this spurious signal conversion can lead to measurement error when performing transport experiments on such materials.&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=2877331&amp;amp;k=14&amp;amp;r=https%3A%2F%2F2877331.hs-sites.com%2Fhow-to-better-characterize-2d-materials-with-large-contact-resistance&amp;amp;bu=https%253A%252F%252F2877331.hs-sites.com&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>resistance measurements</category>
      <category>material characterization</category>
      <category>2D materials</category>
      <pubDate>Thu, 19 Sep 2024 13:53:16 GMT</pubDate>
      <author>webmaster@lakeshore.com (Lake Shore Cryotronics)</author>
      <guid>https://2877331.hs-sites.com/how-to-better-characterize-2d-materials-with-large-contact-resistance</guid>
      <dc:date>2024-09-19T13:53:16Z</dc:date>
    </item>
    <item>
      <title>About the patented technology of the M81-SSM system</title>
      <link>https://2877331.hs-sites.com/about-the-patented-technology-of-the-m81-ssm-system</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/about-the-patented-technology-of-the-m81-ssm-system" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/LakeShoreCryotronics_M81-SSM_Patents.png" alt="LakeShore_M81-SSM_Patented_Technology" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;We often describe our &lt;a href="https://www.lakeshore.com/products/categories/overview/material-characterization-products/measureready-m81-synchronous-source-measure-system/measureready-m81-synchronous-source-measure-system"&gt;M81-SSM synchronous source measure system&lt;/a&gt; as being unique, and what helps make it unique are three technology patents we have obtained for it. Here’s how the technologies covered by the patents benefit material and device characterization applications:&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/about-the-patented-technology-of-the-m81-ssm-system" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/LakeShoreCryotronics_M81-SSM_Patents.png" alt="LakeShore_M81-SSM_Patented_Technology" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;We often describe our &lt;a href="https://www.lakeshore.com/products/categories/overview/material-characterization-products/measureready-m81-synchronous-source-measure-system/measureready-m81-synchronous-source-measure-system"&gt;M81-SSM synchronous source measure system&lt;/a&gt; as being unique, and what helps make it unique are three technology patents we have obtained for it. Here’s how the technologies covered by the patents benefit material and device characterization applications:&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=2877331&amp;amp;k=14&amp;amp;r=https%3A%2F%2F2877331.hs-sites.com%2Fabout-the-patented-technology-of-the-m81-ssm-system&amp;amp;bu=https%253A%252F%252F2877331.hs-sites.com&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>electronic device &amp; semiconductor measurement</category>
      <category>material characterization</category>
      <category>M81 synchronous source measure system</category>
      <pubDate>Mon, 12 Aug 2024 14:56:30 GMT</pubDate>
      <author>webmaster@lakeshore.com (Lake Shore Cryotronics)</author>
      <guid>https://2877331.hs-sites.com/about-the-patented-technology-of-the-m81-ssm-system</guid>
      <dc:date>2024-08-12T14:56:30Z</dc:date>
    </item>
    <item>
      <title>Read our paper on how to choose the right lock-in amplifier</title>
      <link>https://2877331.hs-sites.com/read-our-paper-on-how-to-choose-the-right-lock-in-amplifier</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/read-our-paper-on-how-to-choose-the-right-lock-in-amplifier" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/How-to-Choose-The-Right-Lock-in-Amplifier.png" alt="How to Choose the Right Lock-in Amplifier" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;&lt;a href="https://www.lakeshorecryotronics.com/how-to-choose-the-right-lock-in-amplifier"&gt;&lt;/a&gt;Lock-in amplifiers are important tools for test engineers and material researchers because of their unique ability to precisely measure signals that are otherwise too small to detect amidst noise and other interfering signals. However, researching and evaluating lock-in types for purchase can be confusing. This new paper aims to &lt;a href="https://www.lakeshorecryotronics.com/how-to-choose-the-right-lock-in-amplifier"&gt;simplify selecting and buying a lock-in&lt;/a&gt;. &lt;span style="background-color: transparent;"&gt;It covers:&lt;/span&gt;&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/read-our-paper-on-how-to-choose-the-right-lock-in-amplifier" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/How-to-Choose-The-Right-Lock-in-Amplifier.png" alt="How to Choose the Right Lock-in Amplifier" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;&lt;a href="https://www.lakeshorecryotronics.com/how-to-choose-the-right-lock-in-amplifier"&gt;&lt;/a&gt;Lock-in amplifiers are important tools for test engineers and material researchers because of their unique ability to precisely measure signals that are otherwise too small to detect amidst noise and other interfering signals. However, researching and evaluating lock-in types for purchase can be confusing. This new paper aims to &lt;a href="https://www.lakeshorecryotronics.com/how-to-choose-the-right-lock-in-amplifier"&gt;simplify selecting and buying a lock-in&lt;/a&gt;. &lt;span style="background-color: transparent;"&gt;It covers:&lt;/span&gt;&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=2877331&amp;amp;k=14&amp;amp;r=https%3A%2F%2F2877331.hs-sites.com%2Fread-our-paper-on-how-to-choose-the-right-lock-in-amplifier&amp;amp;bu=https%253A%252F%252F2877331.hs-sites.com&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>noise rejection</category>
      <category>material characterization</category>
      <category>lock-in amplifier</category>
      <pubDate>Tue, 30 Jul 2024 13:02:49 GMT</pubDate>
      <author>webmaster@lakeshore.com (Lake Shore Cryotronics)</author>
      <guid>https://2877331.hs-sites.com/read-our-paper-on-how-to-choose-the-right-lock-in-amplifier</guid>
      <dc:date>2024-07-30T13:02:49Z</dc:date>
    </item>
    <item>
      <title>App brief: noise performance for samples measured in our 8600 Series VSM</title>
      <link>https://2877331.hs-sites.com/app-brief-noise-performance-for-samples-measured-in-our-8600-series-vsm</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/app-brief-noise-performance-for-samples-measured-in-our-8600-series-vsm" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/86-SSVT-Featured-Image.png" alt="Typical Noise Performance for Samples Measured in 8600 Series VSM with Single-Stage Variable Temperature (SSVT) Option" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;On our website, we talk about the measurement capabilities of our &lt;a href="https://www.lakeshore.com/products/categories/overview/material-characterization-products/vsm-systems/8600-series-vsm"&gt;8600 Series VSM&lt;/a&gt; and how the system is designed with a low noise floor, and being highly sensitive, it enables very low magnetic moments to be measured with an acceptable signal-to-noise ratio (SNR). Similarly, in an earlier application note discussing the VSM’s sensitivity and measurement speed, we presented measured RMS noise data for the VSM as a function of pole gap and signal averaging.&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/app-brief-noise-performance-for-samples-measured-in-our-8600-series-vsm" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/86-SSVT-Featured-Image.png" alt="Typical Noise Performance for Samples Measured in 8600 Series VSM with Single-Stage Variable Temperature (SSVT) Option" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;On our website, we talk about the measurement capabilities of our &lt;a href="https://www.lakeshore.com/products/categories/overview/material-characterization-products/vsm-systems/8600-series-vsm"&gt;8600 Series VSM&lt;/a&gt; and how the system is designed with a low noise floor, and being highly sensitive, it enables very low magnetic moments to be measured with an acceptable signal-to-noise ratio (SNR). Similarly, in an earlier application note discussing the VSM’s sensitivity and measurement speed, we presented measured RMS noise data for the VSM as a function of pole gap and signal averaging.&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=2877331&amp;amp;k=14&amp;amp;r=https%3A%2F%2F2877331.hs-sites.com%2Fapp-brief-noise-performance-for-samples-measured-in-our-8600-series-vsm&amp;amp;bu=https%253A%252F%252F2877331.hs-sites.com&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>vibrating sample magnetometer</category>
      <category>magnetic material characterization</category>
      <category>applications brief</category>
      <pubDate>Thu, 18 Jul 2024 18:00:08 GMT</pubDate>
      <author>webmaster@lakeshore.com (Lake Shore Cryotronics)</author>
      <guid>https://2877331.hs-sites.com/app-brief-noise-performance-for-samples-measured-in-our-8600-series-vsm</guid>
      <dc:date>2024-07-18T18:00:08Z</dc:date>
    </item>
    <item>
      <title>How do you know which cryostat is right for you?</title>
      <link>https://2877331.hs-sites.com/how-do-you-know-which-cryostat-is-right-for-you</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/how-do-you-know-which-cryostat-is-right-for-you" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/how-to-select-the-right-research-cryostat-featured.png" alt="A Guide to Buying the Right Research Cryostat" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;&lt;a href="https://www.lakeshorecryotronics.com/guide-to-buying-the-right-research-cryostat"&gt;&lt;/a&gt;Embarking on the journey to purchase a research cryostat can be a complex and crucial decision when you have applications where precise temperature control is paramount. A cryostat is an indispensable tool in areas ranging from material science and quantum computing to astrophysics.&lt;/p&gt; 
&lt;p&gt;But how do you know which type of cryostat is right for your application? &lt;a href="https://www.lakeshorecryotronics.com/guide-to-buying-the-right-research-cryostat"&gt;This new guide can help.&lt;/a&gt; It provides a comprehensive overview of the critical factors to consider when selecting one, including:&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/how-do-you-know-which-cryostat-is-right-for-you" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/how-to-select-the-right-research-cryostat-featured.png" alt="A Guide to Buying the Right Research Cryostat" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;&lt;a href="https://www.lakeshorecryotronics.com/guide-to-buying-the-right-research-cryostat"&gt;&lt;/a&gt;Embarking on the journey to purchase a research cryostat can be a complex and crucial decision when you have applications where precise temperature control is paramount. A cryostat is an indispensable tool in areas ranging from material science and quantum computing to astrophysics.&lt;/p&gt; 
&lt;p&gt;But how do you know which type of cryostat is right for your application? &lt;a href="https://www.lakeshorecryotronics.com/guide-to-buying-the-right-research-cryostat"&gt;This new guide can help.&lt;/a&gt; It provides a comprehensive overview of the critical factors to consider when selecting one, including:&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=2877331&amp;amp;k=14&amp;amp;r=https%3A%2F%2F2877331.hs-sites.com%2Fhow-do-you-know-which-cryostat-is-right-for-you&amp;amp;bu=https%253A%252F%252F2877331.hs-sites.com&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>cryocoolers</category>
      <category>Janis</category>
      <category>cryostats</category>
      <pubDate>Tue, 09 Jul 2024 17:28:53 GMT</pubDate>
      <author>webmaster@lakeshore.com (Lake Shore Cryotronics)</author>
      <guid>https://2877331.hs-sites.com/how-do-you-know-which-cryostat-is-right-for-you</guid>
      <dc:date>2024-07-09T17:28:53Z</dc:date>
    </item>
    <item>
      <title>New app note on T- FORC measurements using our 8600 Series VSM</title>
      <link>https://2877331.hs-sites.com/new-app-note-on-t-forc-measurements-using-our-8600-series-vsm</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/new-app-note-on-t-forc-measurements-using-our-8600-series-vsm" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/featured-img-2.png" alt="T-FORC analysis Using the Model 8600 VSM" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;First order reversal curve (FORC) measurements provide information regarding magnetic interactions and coercivity &lt;span&gt;distributions&amp;nbsp;&lt;/span&gt;that cannot be obtained from hysteresis loop measurements alone. Temperature FORC (T-FORC) measurements take this capability further. They extend the FORC measurement and analysis protocol to magnetic materials that exhibit &lt;i&gt;thermal&lt;/i&gt; hysteresis, such as for determining magnetoelastic or magnetostructural phase transitions as a function of temperature.&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/new-app-note-on-t-forc-measurements-using-our-8600-series-vsm" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/featured-img-2.png" alt="T-FORC analysis Using the Model 8600 VSM" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;First order reversal curve (FORC) measurements provide information regarding magnetic interactions and coercivity &lt;span&gt;distributions&amp;nbsp;&lt;/span&gt;that cannot be obtained from hysteresis loop measurements alone. Temperature FORC (T-FORC) measurements take this capability further. They extend the FORC measurement and analysis protocol to magnetic materials that exhibit &lt;i&gt;thermal&lt;/i&gt; hysteresis, such as for determining magnetoelastic or magnetostructural phase transitions as a function of temperature.&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=2877331&amp;amp;k=14&amp;amp;r=https%3A%2F%2F2877331.hs-sites.com%2Fnew-app-note-on-t-forc-measurements-using-our-8600-series-vsm&amp;amp;bu=https%253A%252F%252F2877331.hs-sites.com&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>application note</category>
      <category>vibrating sample magnetometer</category>
      <category>first order reversal curve (FORC)</category>
      <pubDate>Fri, 28 Jun 2024 17:47:35 GMT</pubDate>
      <author>webmaster@lakeshore.com (Lake Shore Cryotronics)</author>
      <guid>https://2877331.hs-sites.com/new-app-note-on-t-forc-measurements-using-our-8600-series-vsm</guid>
      <dc:date>2024-06-28T17:47:35Z</dc:date>
    </item>
    <item>
      <title>Read our guide on how to identify and manage external noise</title>
      <link>https://2877331.hs-sites.com/read-our-guide-on-how-to-identify-and-manage-external-noise</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/read-our-guide-on-how-to-identify-and-manage-external-noise" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/External_Noise-Guide-Blog2-6-18-24-1.png" alt="Read our guide on how to identify and manage external noise" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;&lt;a href="https://www.lakeshorecryotronics.com/practical-approach-to-understanding-external-noise"&gt;&lt;/a&gt;External noise, also known as interference, introduces measurement error into instrument setups. For numerous research and industrial applications, high measurement precision is required. However, the complex function of external noise often makes it difficult to understand and mitigate.&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://2877331.hs-sites.com/read-our-guide-on-how-to-identify-and-manage-external-noise" title="" class="hs-featured-image-link"&gt; &lt;img src="https://2877331.hs-sites.com/hubfs/External_Noise-Guide-Blog2-6-18-24-1.png" alt="Read our guide on how to identify and manage external noise" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;&lt;a href="https://www.lakeshorecryotronics.com/practical-approach-to-understanding-external-noise"&gt;&lt;/a&gt;External noise, also known as interference, introduces measurement error into instrument setups. For numerous research and industrial applications, high measurement precision is required. However, the complex function of external noise often makes it difficult to understand and mitigate.&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=2877331&amp;amp;k=14&amp;amp;r=https%3A%2F%2F2877331.hs-sites.com%2Fread-our-guide-on-how-to-identify-and-manage-external-noise&amp;amp;bu=https%253A%252F%252F2877331.hs-sites.com&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <category>cryogenic measurement</category>
      <category>mitigating measurement noise</category>
      <pubDate>Thu, 20 Jun 2024 15:00:16 GMT</pubDate>
      <author>webmaster@lakeshore.com (Lake Shore Cryotronics)</author>
      <guid>https://2877331.hs-sites.com/read-our-guide-on-how-to-identify-and-manage-external-noise</guid>
      <dc:date>2024-06-20T15:00:16Z</dc:date>
    </item>
  </channel>
</rss>
